The Solar Energy Testing Center
With grid-connected PV inverter as its testing object, the Solar Energy Testing Center can carry out test in accordance with mainstream testing standards at home and abroad, and facilitate domestic and foreign customers to expand European and American markets. The main customers include: Sungrow Power Supply, CHINT, TBEA and ABB, SMA, Schneider, etc.
With grid-connected PV inverter as its testing object, the Solar Energy Testing Center can carry out test in accordance with mainstream testing standards at home and abroad, and facilitate domestic and foreign customers to expand European and American markets. The main customers include: Sungrow Power Supply, CHINT, TBEA and ABB, SMA, Schneider, etc.
Main testing standards:
Grid-connected PV Inverter:
CGC/GF001-2009 Technical Specification and Test Method of Grid-connected PV Inverter below 400V
UL1741-2010 Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources
IEEE 1547.1-2005 Conformance Test Procedures for Equipment Interconnecting Distributed Resources with Electric Power Systems
IEC 62109-1(Edition 1.0):2010 Safety of Power Converters for Use in Photovoltaic Power Systems - Part 1: General Requirements
DIN VDE V 0126-1-1-2013 Automatic Disconnection Device between a Generator and the Public Low-voltage Grid
VDE-AR-N 4105-2011 Power generation systems connected to the low-voltage distribution network - Technical minimum requirements for the connection to and parallel operation with low-voltage distribution networks
BDEW-2008 Technical Guidelines for Generating Plants Connected to the Medium-Voltage Network
CGC/GF004-2011 Technical Specification of Grid-connected PV Inverter
GB/T 19964-2012 Technical Requirements for Connecting Photovoltaic Power Station to Power System
GB/T 29319-2012 Technical Requirements for Connecting Photovoltaic Power System to Distribution Network
TR3-2011 Technical Guidelines for Power Generating Units and Systems Connected to Medium-voltage, High-voltage and Ultra-high-voltage Power Grid
TR4-2010 4 Technical Requirements for Electrical Performance Simulation Modeling and Model Validation of Power Generating Units and Systems
IEC 62109-2(Edition 1.0):2011 Safety of power converters for use in photovoltaic power systems - Part 2: Particular requirements for inverters
AS_NZS_3100-2009 Approval and test specification—General requirements for electrical equipment
NB/T 32010-2013 Anti-islanding Testing Code for Inverter of Utility-interconnected Photovoltaic Power Station
NB/T 32014-2013 Testing Code for Anti-islanding of Photovoltaic Power Station
AS4777.3-2005 Grid Connection of Energy Systems via Inverters Part 3: Grid Protection Requirements
AS4777.2-2005 Grid Connection of Energy Systems via Inverters Part 2: Inverter Requirements
EN 50530-2010 Overall Efficiency of Grid Connected Photovoltaic Inverters
G83/1-1-2008 Recommendations for the connection of small-scale embedded generators in parallel with low-voltage distribution systems
GB/T 30152-2013 Testing code for photovoltaic generation system connected to distribution network
NB/T 32008-2013 Testing code for power quality of inverters used in photovoltaic power station
GB/T31365-2015 Testing code for photovoltaic power station connected to power grid
GB/T 30427-2013 Technical requirements and test methods for grid-connected PV inverters
B.E.2551-2013 PEA Requirements for Connection to Power Grid
IEC 62116(Edition 2.0):2014 Utility-interconnected photovoltaic inverters - Test procedure of islanding prevention measures
NB/T 32009-2013 Testing code of voltage and frequency response for inverter of photovoltaic power station
CGC/GF035-2013 Technical specification for China efficiency of grid connected PV inverters
Grid-connected PV Power Station:
CNCA/CTS 0004-2010 Basic acceptance requirements for grid-connected PV systems
IEC 62446(Edition1.0):2009 Grid Connected Photovoltaic Systems - Minimum System Documentation, Commissioning Tests and Inspection Requirements
GB/T 19964-2012 Technical Requirements for Connecting Photovoltaic Power Station to Power System
GB/T 29319-2012 Technical Requirements for Connecting Photovoltaic Power System to Distribution Network
NB/T 32005-2013 Testing code for low voltage ride through of photovoltaic power station
NB/T 32006-2013 Testing code for power quality of photovoltaic power station
NB/T 32007-2013 Testing code for power control of photovoltaic power station
NB/T 32013-2013 Testing code for voltage and frequency response of photovoltaic power station
GB/T 30152-2013 Testing code for photovoltaic generation system connected to distribution network
GB/T 29321-2012 Technical specification for reactive power compensation of PV power station
GB/T20513-2006 Photovoltaic system performance monitoring - Guidelines for measurement, data exchange and analysis
NB/T 32010-2013 Anti-islanding Testing Code for Inverter of Utility-interconnected Photovoltaic Power Station
NB/T 32014-2013 Testing Code for Anti-islanding of Photovoltaic Power Station
NB/T 32008-2013 Testing code for power quality of inverters used in photovoltaic power station
CGC/GF035-2013 Technical specification for China efficiency of grid connected PV inverters
Energy Storage Converter:
NB/T 31016-2011 General specification for power control system of battery energy storage system
NB/T33015-2014 Technical guideline for electrochemical energy storage system interconnecting with distribution network
NB/T33016-2014 Testing code for electrochemical energy storage system interconnecting with distribution network
NB/T33014-2014 Operation and control specification for electrochemical energy storage system interconnecting with distribution network
Combiner Box:
CGC/GF002-2010 Technical Specifications of PV Combiner Box